CT CHEST/ABDOMEN/PELVIS TRAUMA PROTOCOL C+ (last updated 6/20/2016, last reviewed 02/07/2022)
(last updated 6/20/2016, last reviewed 02/07/2022)
INDICATION: Trauma
SERIES
- 3mm Axial Chest Soft Tissue
- 1mm Axial Lung
- 3mm Axial A/P
- 3mm Coronal chest only (Lung windows)
- 3mm Sagittal chest only (Lung windows)
- 3mm Coronal A/P only
- 3mm Sagittal A/P only
| CHEST | ABDOMEN/PELVIS |
POSITIONING/MODE
|
supine/helical |
supine/helical |
kV/mA/rot time
|
120kV/auto mA/0.5 sec |
120kV/auto mA/0.5 sec |
DETECTOR COLLIMATION
|
16 x 1.5mm (S16) 24 x 1.2mm (D64) |
16 x 1.5mm (S16) 24 x 1.2mm (D64) |
SLICE THICKNESS
|
3mm |
3mm |
PITCH
|
1 to 1.5 |
1 to 1.5 |
TABLE FEED
|
4.8 cm/sec (S16) 5.8 cm/sec (D64) |
4.8 cm/sec (S16) 5.8 cm/sec (D64) |
KERNAL
|
std and lung |
std |
SFOV
|
large |
large |
COVERAGE
|
thoracic inlet -> diaphragm |
diaphragm -> pubic symphysis |
ACQUISITION
|
craniocaudal |
craniocaudal |
ORAL CONTRAST
|
yes |
yes |
IV CONTRAST
|
100 mL Isovue 300 30 mL saline |
yes |
INJECTION RATE
|
2.5 mL/sec |
--- |
SCAN DELAY
|
Care bolus @ Ascending Aorta (threshold 100 HU ~15 sec) |
35 sec delay btw C and A/P (S16) 38 sec delay btw C and A/P (D64) |
RESPIRATION
|
Inspiration |
Inspiration |
POSTPROCESSING
|
3mm Cor and Sag (lung windows, chest only) |
3mm Cor and Sag (A/P only) |
NOTES:
Please perform a bone reconstruction algorithm (axial) for the pelvis.
Check to make sure that the spleen is homogeneously enhancing. If the spleen is not homogeneously enhancing and still has a heterogeneous “wavy” enhancement, please immediately repeat a scan thru the spleen and liver.
***For pediatric patients (<18 yo) follow ALARA principle and use pediatric specific technical parameters per respective CT scanner***