CT ABDOMEN C- (last updated 08/17/15, last reviewed 02/07/2022)
INDICATION: Same as CT Abdomen C+ with contraindication to IV contrast
SERIES
- 3mm Axial
- 3mm Coronal
- 3mm Sagittal
Click to edit table header | |
POSITIONING/MODE
|
supine/helical |
kV/mA/rot time
|
per scanner protocol CareDose/iDose/ASIR Care kV 120 to 140 kVp </= 1 sec |
SLICE THICKNESS
|
3mm |
PITCH
|
0.6 to 1.2 |
KERNAL
|
std |
SFOV
|
300 to 350 mm |
COVERAGE
|
diaphragm -> iliac crest |
ACQUISITION
|
craniocaudal |
ORAL CONTRAST
|
Per Dept Protocol |
IV CONTRAST
|
none |
RESPIRATION
|
Inspiration |
POSTPROCESSING
|
3mm Coronal and Sagittal |
NOTES: Give 1-2 cups of water just prior to scanning the patient in order to distend the stomach.
***For pediatric patients (<18 yo) follow ALARA principle and use pediatric specific technical parameters per respective CT scanner***