CTA CAROTIDS (updated 10/28/2020, reviewed 10/28/2020)
INDICATION: Carotid stenosis, carotid dissection.
SERIES
- 1 mm axial CTA
- 2 mm coronal
- 2 mm sagittal
- 2mm oblique sagittal R and L carotid
- 3D volume rendered reformats
| |
POSITIONING/MODE
|
Supine/helical |
kV/mA/rot time
|
120 kV/200 mAs/<1 sec |
DETECTOR COLLIMATION
|
16 x 0.75mm (S16) 64 x 0.6mm (D64) |
SLICE THICKNESS
|
1mm |
PITCH
|
</=1 |
KERNAL
|
soft tissue (B30f medium smooth ax, B20f recon) soft tissue (B30f medium smooth ax, B20f recon) |
SFOV
|
<30cm |
COVERAGE
|
aortic arch -> anterior cranial fossa/orbital roof |
ACQUISITION
|
caudocranial |
IV CONTRAST
|
80 mL Isovue 370 |
INJECTION RATE
|
4 ml/sec |
SCAN DELAY
|
Bolus tracking @ aortic arch (~20 sec) |
POSTPROCESSING
|
Coronal 2mm, 2mm oblique sagittal R and L carotid, 3D reformats
|
NOTE: Oblique sagittal reformats are performed parallel to a line drawn between the internal and external carotids at the bifurcation.